50kw 400Vac wind generator/PMG/controller/inverter
Characteristics
1. Optimum aerodynamic shape design: high efficiency, low noise.
2. Centrifugal pitch controlled mechanism: 3m/s low wind speed startup; 3-12m/s wind speed, following wind rotor rotate speed to adjust blade angle at optimum TSR, run in high efficiency; over rated wind speed, wind rotor never goes to over speed and has stable control; 3-35m/s wind speed, wind turbine can run smoothly.
3. Direct drive permanent magnet generator, low startup resistance moment, constant running ability of over loading 1.5 times, maintenance free for more than 30000 hour.
4. Safety control: has aerodynamic brake, electric magnet brake, mechanical brake and manual stop mechanism.
5. Sealed slip ring, no cable twist;
6. Streamline design.
7. Long acting anticorrosive treats, no corrosion in 15years.
More products
More products(click the picture)
50KW wind generator 70/100/150RPM/AC400V techncial data sheet:
1.Technical Details |
Rated Power(KW): | 50 | 50 | 50 |
Rated Speed(RPM): | 70 | 100 | 150 |
Rated Torque(N*M): | 7579 | 5306 | 3537 |
Rated Voltage(V): | AC400 |
Rated Current(A): | 72.17 |
Insulation Class: | F |
Efficiency(>%): | 90 |
PMG Collocation: | Y Connection,Three Phase Three Wires, Alternator |
Service Life: | More Than 20 years |
Working Environment: | -25Centigrade——40Centigrade |
Speed Range: | 0-84rpm | 0-120rpm | 0-180rpm |
2.Mechanical Details |
Mounting Means: | Vertical |
Weight(Kg): | 3100 | 1500 | 1100 |
Start Torque(<N*M): | 102.3 | 72 | 48 |
3.Material Details |
Shaft Material: | 40Cr Steel with quenching and tempering Treatment |
Bearing: | C&U or for your order |
Shell Material: | Steel |
Winding Temperature Class: | 150Centigrade |
Permanent Magnet Material: | Rare Earth NdFeB |
Permanent Magnet Material Temperature Class: | 150Centigrade |
Core: | High Grade Cold Rolling Silicon Sheet 50WW470 |
Protection Grade: | IP54 |
Off grid wind power system
50KW off grid wind charge controller
Type | 50KW-360Vdc |
Wind turbine rated power | 50KW |
Wind turbine max. power | 80KW |
Battery | 420Vdc |
Function | Rectifier,charge, control |
Display mode | LCD |
Display content | Wind turbine voltage, wind turbine current, wind turbine power, solar panel voltage, solar panel current, solar panel power, battery voltage, charge current |
PWM constant pressure voltage | >435Vdc |
3-phase load 1 voltage of the wind turbine | 440±5Vdc |
3-phase load 2 voltage of the wind turbine | 445±5Vdc |
3-phase load 3 voltage of the wind turbine | 450±5Vdc |
Recovery charging voltage of the wind turbine | 405±5Vdc |
Low-voltage of the battery | 300±5Vdc |
Self-provided connecting wire of the 3-phase dump load | >16mm² |
Self-provided connecting wire of the battery | >30mm² |
PWM fuse | 100A |
Charging fuse | 160A |
Work environment temperature | -30-60°C |
Relative humidity | <90% No condensation |
Noise (1m) | <40dB |
Degree of protection | IP20(Indoor) |
Cooling method | Forced air cooling |
*Communication interface (optional) | RS485/USB/GPRS/Ethernet |
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C |
Size of the controller (mm) | 690*590*1300 |
Weight of the controller | 120Kg |
Size of the dump load (mm) | 690*450*1000 690*450*1000 |
Weight of the dump load | 160 Kg |
50KW wind charge controller
50KW off grid three phase inverter technical data sheet
Type | NB240-62.5KSZ | NB380-62.5KS |
DC input | Input rated voltage | 240 VDC | 380 VDC |
Input rated current | 260 A | 165A |
Input DC voltage range | 190-650 VDC | 300-490VDC |
AC input (AC Bypass) | Allow input voltage range | 240 VAC / 380 VAC / 400VAC/415 VAC ± 15% VAC |
Input rated current | 159A / 95A / 91A/ 86.8A |
Bypass transfer time | ≤4 ms |
AC output | Rated capacity | 62.5KVA |
Output rated power | 50KW |
Output rated voltage and frequency | 240 VAC / 380 VAC / 400VAC/415 VAC ,50Hz / 60Hz |
Output rated current | 159A / 95A / 91A/ 86.8A |
Output voltage accuracy | 240 VAC / 380 VAC / 400VAC/415 VAC± 2% |
Output frequency accuracy | 50Hz / 60Hz ±0.05% |
Waveform distortion (THD). (Linear load) | ≤3% |
Dynamic response time (Load 0←→100%) | 5% |
Power factor (PF) | 0.8 |
Overload capacity | 120%,3 minutes,150%,10 second |
Crest factor (CF) | 3:1 |
Inverter efficiency | 90% |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB |
Ambient temperature | -10℃~+50℃ |
Humidity | 0~90%,No condensation |
Altitude | ≤5000 m |
Pure Sine Wave | Yes |
Equipped with copper transformer | Yes, 3 pcs |
Solar Charger | Available |
Battery Priority | optional |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection |
Size(mm) | 660*1300*1600mm |
Weight(kg) | 450kg |
On grid wind power system
50kw on grid wind controller technical data sheet
Type | FKJ-GT-50KW | FKJ-GT-100KW |
Wind turbine rated power | 50KW | 100KW |
Wind turbine Max. power | 100KW | 200KW |
Function | Rectifier,charge, control |
Display mode | LED |
Display content | DC output voltage, |
PWM constant voltage | ≥650dc | ≥650dc |
wind turbine 3-phase dump load voltage1 | 670±5Vdc | 670±5Vdc |
three-phase dump load 1 delay time | 12-20 min | 12-20 min |
wind turbine 3-phase dump load voltage2 | 680±5Vdc | 680±5Vdc |
three-phase dump load 2 delay time | 12-20 min | 12-20 min |
wind turbine 3-phase dump load voltage3 | 700±5Vdc | 700±5Vdc |
three-phase dump load 3 delay time | 12-20 min | 12-20 min |
Low-voltage | ≤200Vdc | ≤200Vdc |
PWM dump load fuse | 63A | 100A |
Fuse of DC output | 100A | 200A |
Self-provided connecting wire of the PWM dump load (mm²) | >10mm² | >20mm² |
Self-provided connecting wire of the dump load 1(mm²) | >10mm² | >16mm² |
Self-provided connecting wire of the dump load 2(mm²) | >10mm² | >16mm² |
Self-provided connecting wire of the dump load 3(mm²) | >10mm² | >16mm² |
Work environment temperature | -30-60°C |
Relative humidity | <90% No condensation |
Noise (1m) | <40dB |
Degree of protection | IP20(Indoor) |
Cooling method | Forced air cooling |
*Communication interface (optional) | RS485/USB/GPRS/Ethernet |
*Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C |
Size of the controller (mm) | 690*590*1300 mm | 690*590*1300 mm |
Weight of the controller | 120Kg | 120Kg |
Size of the dump load (mm) | 760*520*1200(3pcs) | 760*520*1200(4pcs) |
Weight of the dump load | 330Kg | 440Kg |
50KW on grid wind inverter techncial data sheet:
Model | DMWG-50KS |
Isolation | Frequency transformer isolation |
Maximum input voltage allows | 780Vdc |
Maximum Power Point Tracking (MPPT) range | 450Vdc-780Vdc |
Nominal AC output power | 55KW |
Max. AC output power | 55KW |
THD of AC current | <3%(Rated power) |
Power factor | >0.99 |
Max. efficiency | 94% |
Euro efficiency | 92% |
Allowed Grid Voltage Range | 310~450Vac |
Allowed Grid Frequency Range | 47.5~51.5Hz |
Internal power consumption an night | <10W |
Automatically put into operation conditions | DC input and power to meet the requirements, the inverter automatically run |
Automatic restart after power failure time | 2min |
Protection | Reverse polarity, short circuit, island, overheating and overload etc |
Comm. interfaces | RS485(Modbus Agreement) |
Operating Temp. | -25℃~+60℃ |
Relative humidity | 0~90%,Non-condensing |
Altitude(m) | 6000 meters (over 2000 m with derating required) |
Cooling method | Forced air cooling |
Noise | ≤60dB |
Protection degree | IP20(indoor) |
Dimensions (W * D * H mm) | 800*600*2060 |
Communications monitoring | Inverter via RS485 communication for start-stop control and routine data monitoring |